HVAC ResVent 62.2 Mobile App for iOS
(Please note: This app is no longer available on the iOS App Store. If you are interested in accessing this app in other ways, please contact us.)
ResVent 62.2 allows you to quickly perform comprehensive whole-building ventilation requirements for residential buildings following the most recent versions of this important standard, 62.2-2007 and 62.2-2010, for both new and existing dwellings.
First published in 2003, ANSI/ASHRAE 62.2, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, requires minimum whole-building and local (bathrooms and kitchens) ventilation rates for dwellings.
ASHRAE 62.2 . . . “applies to spaces intended for human occupancy within single-family houses and multi-family structures of three stories or fewer above grade, including manufactured and modular houses.” (ASHRAE 62.2-2007 and 62.2-2010, page 2.)
ResVent 62.2 allows you to quickly perform comprehensive whole-building ventilation requirements for residential buildings following the most recent versions of this important standard, 62.2-2007 and 62.2-2010, for both new and existing dwellings.
First published in 2003, ANSI/ASHRAE 62.2, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, requires minimum whole-building and local (bathrooms and kitchens) ventilation rates for dwellings.
ASHRAE 62.2 . . . “applies to spaces intended for human occupancy within single-family houses and multi-family structures of three stories or fewer above grade, including manufactured and modular houses.” (ASHRAE 62.2-2007 and 62.2-2010, page 2.)
Summary of Features
- Math-on-the-Fly, allowing you to calculate results within an input box, for example, you can calculate volume by entering 40*25*8. Press “Done” and the answer appears in the input box! You may use addition, subtraction, multiplication, division, or exponents.
- Reporting feature allows you to e-mail a report of your entries and results back to your office or to the client.
- The weather factors – over 200 – for the U.S. and Canada are included on a picker list for easy selection. These factors are from ASHRAE Standard 136, A Method of Determining Air Change Rates in Detached Dwellings.
- Slider controls for the easy entry of most data. The slider controls allow you to quickly perform “what-if” analysis, such as finding the measured leakage rate at which the whole-building ventilation requirement becomes zero.
- Whole-building mechanical airflow requirement result is displayed on each input screen so you can view the instantaneous result of your input changes.
- Fan Run-Time Tool for finding the number of minutes per hour your whole-building fan must operate.
- Calculation of the infiltration credit for Standards 62.2-2007 and 62.2-2010 using ASHRAE Standards 119, Air Leakage Performance for Detached Single-Family Residential Buildings; and 136, A Method of Determining Air Change Rates in Detached Dwellings. The infiltration credit is needed for determining the whole-building ventilation rates in existing dwellings.
- Alternative Compliance Tool allows you to determine the alternative compliance supplement used for existing dwellings when using Standard 62.2-2010. You may select up to five bathrooms for this procedure. This procedure is found in Appendix A of the 62.2-2010.
- When creating a new project, you may use the included default project or any other existing project as the basis for your new one. The number of projects is only limited by the memory of your hardware.
- Includes a comprehensive help screen.
- The global settings allow you to choose ASHRAE 62.2-2007 or ASHRAE 62.2-2010 for complete whole-building ventilation compliance with either. You may also select IP or SI units for your calculations.